ΔP CONTROL FLOW LOOP / FIELD RATE
Gongyi Xinqi Polymer Co., Ltd.Polyacrylamide Friction ReducerPRESSURE RESPONSE DESKSEND WATER & RATE →
Trial and delivery control

Friction Reducer Batch Qualification for Repeat Supply

Link friction-reducer sample approval to incoming lots using identity checks, retained reference material, repeatable preparation and matched pressure-response tests.

WATER
actual analysis
FLOW
matched condition
ΔP
complete trace
Laboratory flow loop with differential pressure instruments for friction-reducer testing
PURCHASING / WATER AND PRESSURE

Published · Updated · Gongyi Xinqi Polymer Co., Ltd.

SHEET INDEX01Define which identity was approved02Check the incoming shipment before testing03Repeat preparation before judging performance04Compare the complete pressure trace05Investigate before assigning responsibility06Close the loop with change control
01

Define which identity was approved

Record the accepted formulation code, form, supplier sample or lot, water envelope, preparation and hydraulic evidence. A broad polyacrylamide description is not a sufficient repeat-supply identity. State whether the approval came from bench screening alone or included a controlled field trial.

The trial acceptance record should connect the technical release to the commercial order. Retain the evidence and reference material under suitable conditions so later discrepancies can be investigated factually.

02

Check the incoming shipment before testing

Match product code, lot, package markings, seal condition and COA to the order. Segregate mismatched or damaged material before unloading into shared equipment. Sampling should follow an agreed safe procedure that preserves representativeness and does not introduce contamination.

Record collection time, container identity and any abnormal observations. A sample drawn from an unrepresentative point or after uncontrolled mixing can generate an apparent batch difference. Keep chain-of-custody information proportionate to the decision risk.

03

Repeat preparation before judging performance

Use the agreed water, temperature, stock concentration, wetting or inversion procedure and elapsed time. Check meter or weighing accuracy. Differences in make-down can be larger than the product effect being investigated, particularly when comparing dry powder with an emulsion reference.

Include a retained accepted sample where its condition is suitable for comparison. If the retained material has also aged or experienced an excursion, document that limitation. Do not treat an uncertain reference as an unquestionable standard.

04

Compare the complete pressure trace

Run matched water blanks and the reference under stable rate, geometry and measurement settings. Compare early response and retained performance at the agreed product and active basis. A single favourable peak does not demonstrate lot equivalence.

The loop evaluation method supports repeatable comparisons. Repeat a decisive discrepancy before rejecting supply and preserve raw traces, preparation records and actual feed quantities. Avoid inventing a universal acceptable percentage difference without instrument and process context.

05

Investigate before assigning responsibility

Review water variation, sensor drift, preparation age, pump calibration, additive changes and sample history. Separate a verified product nonconformance from a process condition outside the approved envelope. Both may require action, but they require different corrective measures.

Agree investigation, retest and release responsibilities with the supplier and internal quality team. Keep suspect material identifiable while a decision is pending. Do not use additional dose as a permanent workaround for an unexplained discrepancy without technical approval.

06

Close the loop with change control

Record accepted, conditional or rejected status, supporting results and the responsible reviewer. Connect that decision to the actual lot and remaining inventory. Material formulation or process changes should trigger the appropriate requalification rather than inherit the old approval automatically.

Send the purchase identity, comparison method and observed discrepancy through the batch qualification enquiry. Maintain a repeat-supply plan that can reproduce acceptance instead of relying on the memory of a successful sample test.

WhatsAppEmail