ΔP CONTROL FLOW LOOP / FIELD RATE
Gongyi Xinqi Polymer Co., Ltd.Polyacrylamide Friction ReducerPRESSURE RESPONSE DESKSEND WATER & RATE →
Product specification

Friction Reducer Active Content and COA Specifications for Purchasing

Distinguish active polymer, total solids, density and viscosity when specifying friction-reducer quality and comparing emulsion or powder quotations.

WATER
actual analysis
FLOW
matched condition
ΔP
complete trace
Unbranded friction-reducer totes dry polymer bags and traceable samples in a clean warehouse
PURCHASING / WATER AND PRESSURE

Published · Updated · Gongyi Xinqi Polymer Co., Ltd.

SHEET INDEX01Define what the percentage measures02Normalize mass and volume carefully03Use viscosity as a controlled quality measurement04Connect COA values to the accepted material05Set acceptance limits with an application rationale06Keep the quotation and test basis aligned
01

Define what the percentage measures

Active polymer, nonvolatile solids and dry matter can describe different analytical quantities. Emulsion formulations may include carrier and surfactant components; dry products can contain moisture and formulation constituents. Ask the supplier which fraction is being reported, the test method and the unit basis before using a percentage to compare offers.

The product-form comparison establishes why activity affects purchasing but cannot replace application tests. A high total-solids figure is not automatically an equivalent high active-polymer figure.

02

Normalize mass and volume carefully

A polymer mass fraction is a mass-based quantity. When product is metered or invoiced by volume, the formulation density at an appropriate temperature is needed to convert to mass. Record the density source and measurement conditions rather than borrowing a value from another grade or assuming the product behaves like water.

Keep product dose, polymer dose and dilution concentration as separate fields. An otherwise correct calculation can become misleading if stock-solution volume is entered as supplied product volume. Confirm the actual material at the metering point and preserve the conversion with the test record.

03

Use viscosity as a controlled quality measurement

Specify solution concentration, water, temperature, preparation and instrument method if viscosity forms part of receiving control. Viscosity values obtained by different procedures are not directly comparable. A number without its method is particularly weak evidence when polymer hydration and mechanical history affect the result.

Do not interpret a higher viscosity as an automatic improvement in turbulent friction reduction. The hydraulic acceptance still requires the agreed pressure-response test. Viscosity can support identity or consistency checks when its relationship to the approved grade has been established.

04

Connect COA values to the accepted material

Request the lot-specific COA with product code, lot identification and applicable results. Clarify whether a value is measured for that lot, a typical property or a specification limit. Keep the current SDS separately because safety information and analytical release data have different purposes.

The supply-quality checklist links documents to sample approval and receiving. Resolve missing methods or ambiguous units before shipment rather than asking the receiving team to interpret conflicting paperwork after unloading.

05

Set acceptance limits with an application rationale

Use supplier capability, test repeatability and the approved material to agree meaningful limits. Avoid adding an arbitrary molecular-weight or viscosity minimum simply because it appears demanding. A limit that lacks a method can reject good supply or accept unsuitable material while creating an appearance of precision.

Include a reference-water preparation or loop check where warranted by risk. Define retest, investigation and quarantine responsibilities. Small analytical differences should be interpreted with the agreed measurement procedure, not automatically treated as proof of formulation substitution.

06

Keep the quotation and test basis aligned

Ask for the same active definition on the quotation, sample data and order specification. If the basis changes, recalculate price and addition consistently before deciding whether the offer has improved. Record any unresolved uncertainty rather than presenting a falsely exact cost comparison.

Attach the proposed activity, density and quality requirements to the friction-reducer specification enquiry. Use the dose-unit calculation guide for conversions while retaining the actual measured field and laboratory quantities.

WhatsAppEmail