Polyacrylamide Friction Reducer Shear Degradation

Diagnose friction-reducer performance loss across pumps, valves and restrictions using paired pressure tests, preparation controls and representative shear.

WATER
actual analysis
FLOW
matched condition
ΔP
complete trace
Laboratory flow loop with differential pressure instruments for friction-reducer testing
CONTROL NOTE 06 / SHEAR

Published · Updated · Gongyi Xinqi Polymer Co., Ltd.

SHEET INDEX01Draw the fluid path02Preserve a time control03Use matched analysis04Verify preparation first05Reproduce one element06Measure retained response07Review equipment options08Set retest triggers09Connect the test result to a purchase decision10Evidence and purchasing interpretation
01

Draw the fluid path

Mark injection, mixing, pumps, valves and sample points.

Locate plausible shear sources.

02

Preserve a time control

Hold an unprocessed sample for comparison.

Hydration and time can otherwise mimic degradation.

03

Use matched analysis

Control water, temperature, elapsed time and loop condition.

Paired samples need one method.

04

Verify preparation first

Inspect wetting, inversion and concentration.

Incomplete hydration is not shear degradation.

05

Reproduce one element

Use a documented pump or restriction exposure.

Unbounded high-speed mixing is difficult to interpret.

06

Measure retained response

Compare full differential-pressure traces before and after exposure.

Include variability.

07

Review equipment options

Check throttling, recirculation and pump operation.

Chemistry may not be the only correction.

08

Set retest triggers

Repeat after rate, pump, water or product changes.

Keep the accepted path with the release record.

09

Connect the test result to a purchase decision

Keep the approved water, preparation and pressure-response record with the proposed product identity. Resolve the next commercial question using Friction Reducer and Breaker Compatibility for Purchasing.

The selected grade, test conditions and any operating limitations should remain traceable through quotation, trial supply and receiving. A change in water, formulation or equipment calls for review rather than automatic acceptance against an old result.

10

Evidence and purchasing interpretation

Take paired samples around a suspected equipment element only when the operator can do so safely under an approved procedure. Use a time-matched sample that has not passed through the element as a control. Record rate, pressure, temperature, residence and preparation state, because incomplete development and dilution can resemble loss of polymer performance.

Laboratory exposure should have a defined purpose. A high-speed mixer can impose severe mechanical conditions but may not reproduce the field device. Document the apparatus, duration and concentration and compare retained hydraulic response, not only a viscosity number taken by an unrelated method. Keep the complete traces and repeat the critical point.

Corrective action can include preparation, hydraulic-path or product changes. Avoid assigning a weak result to chain damage until simpler metering and hydration explanations have been examined. After any correction, repeat the matched comparison and connect the accepted equipment path to the purchasing release so later hardware changes trigger a review.